The question this pilot must answer
The IoT Frontier Model rests on one claim: experience from many machines helps the next machine. The first test of that claim is narrow on purpose. One forecasting task, one kind of fleet, and a comparison that can come out either way:
- Joint model: trained, with differential privacy, on the approved data of several operators.
- Single-operator model: the same model, trained the same way on one operator’s data alone, in the same release (the live demo runs this comparison on synthetic data).
- Test: both scored on held-out sites that took no part in training, from operators in the pilot.
If the joint model is not measurably better, we will say so and not scale the task. If it is, the next step is more tasks and device types on the same footing, which is the road toward an industry model that this pilot does not yet show.
The task we propose
Forecast tomorrow’s energy throughput for each storage site: kilowatt-hours charged and discharged on the next day, from the site’s recent daily history and coarse public attributes.
- It matters to operators: dispatch plans, maintenance windows and degradation estimates all start from expected throughput.
- It fits how TLAY works today: one signed, encrypted record per device per day, bound to one policy, with a per-device privacy budget.
- It can be scored honestly: a forecast is either close to the next day’s metered value or it is not, on sites the model has never seen.
We will fix the exact target and horizon with founding partners before any data flows, and write them into the policy that owners consent to.
Who we are looking for
| Fleet | Why it helps | What we would ask |
|---|---|---|
| Battery energy storage, commercial or behind the meter | The core of the task: many similar sites under different climates and loads | Daily telemetry per site, ideally with a year of history to cover the seasons |
| Solar plus storage | Weather-driven throughput, the hardest case for a single operator to learn from its own sites | The same daily telemetry, plus the site’s coarse climate zone |
| EV charging sites with storage | Demand patterns that differ from stationary storage, testing whether experience transfers | Daily energy per site; no driver or session data |
A device or its gateway must be able to sign and encrypt one record a day: with TLAY’s BoAT on the device, or through a gateway that holds the device key. We will help with the integration; we will not ask for a copy of your data.
Data fields, by category
Only daily aggregates, only what the task needs. The energy record exists: a versioned record type (energy_daily_v1) with a closed set of integer fields in fixed units, signed by the site and encrypted to the policy like every TLAY record. A record in the wrong unit or range is rejected, not guessed at. The live demo runs it with 1000 synthetic storage units on 20 sites. We will confirm the fields and ranges with founding partners before any real data flows.
| Category | Examples | Resolution and unit |
|---|---|---|
| Energy | Energy charged; energy discharged | Per UTC day, kWh |
| Battery state | Minimum, maximum and mean state of charge; equivalent full cycles | Per UTC day, percent and cycles |
| Temperature | Minimum and maximum cell or enclosure temperature | Per UTC day, °C |
| Availability | Hours available; count of fault stops | Per UTC day, hours and count |
| Site class | Capacity band, chemistry class, climate zone | Coarse public categories, not exact values or locations; public metadata kept beside the record, not in it (the demo uses a site id only) |
Not collected: customer or driver identity, exact location, tariffs and billing, charging sessions, or anything else about people. Dates are UTC calendar days in ISO 8601; units are fixed in the schema, so a record in the wrong unit fails validation instead of being guessed at.
Consent, scope and retention
- One policy, one task. Each owner signs consent to a policy that names this task, these fields, the days covered, the only program image allowed to read the data and the outputs it may release. A different task needs a new policy and new consent.
- Privacy budget per device. The policy states the privacy unit and the budget each device may spend; budget is reserved before anything is decrypted and never refunded. The values will be agreed with partners, not set by us alone.
- Retention. How long encrypted records are kept, and what happens to them when the policy ends, is written into the policy before anyone joins.
- Withdrawal. An owner can withdraw consent at any time and gets a signed receipt. Withdrawal stops later releases from using their devices; it cannot remove their contribution from a model already released.
- What partners see of each other: nothing at record level. Other partners receive only results the policy allows: noised model weights and aggregate metrics.
How the result will be judged
The evaluation design is fixed and published to the partners before training starts, and the result is reported whether or not the joint model wins.
| Part | Plan |
|---|---|
| Held-out sites | Sites are split by site, not by day: a held-out site contributes no data to training. Each operator in the pilot keeps some of its sites held out. |
| Baselines | A simple per-site baseline, such as the mean of the past seven days; and the single-operator model above, scored on the same held-out sites. |
| Metric | Mean absolute error in kWh per site-day, overall and per operator, with the privacy budget each model spent. |
| Where it runs | Inside the approved workload: held-out data is decrypted only there, and only noised aggregate errors leave. Our training workload already does this for held-out devices of the same run (you can see it in the live demo); it can hold out whole sites, as the demo does with 4 of its 20. The single-operator model trains in the same release, on half of each device's privacy budget, and only the noised errors of both leave. On synthetic data it has also run in the attested cloud pilot: on November 14, 2026 the energy forecast scored on held-out operator op-4 at 67.1 kWh mean absolute error, against 80.9 for op-1 alone and 85.9 for the 7-day mean (evidence on the Trust page). That run did not score yesterday’s value, the simplest forecast an operator already has. A pilot run of November 21, 2026 did, inside the workload: 65.2 kWh for the forecast against 70.4 for yesterday’s value, within the noise (±14.4 kWh). Replayed on the same synthetic generator over 100 seeds and 8 next days per held-out operator, the released energy forecast beats yesterday’s value by only about 2% on average, and on 54% of operator-days; the fault-stop forecast beats it on 99%. On these fleets a day’s energy is mostly yesterday’s, so the energy forecast adds little over persistence there; real fleets are not measured yet. |
| Success | A gain over both baselines that partners agreed in advance is worth having. We are not stating a number before we have data. |
What exists today, and what does not
The pipeline this pilot would use has run in our cloud pilot: owners’ consent on their own devices, keys released only to an attested program, a per-device budget reserved before decryption, DP-SGD training in Google Cloud Confidential Space and a signed receipt for the result. That run used synthetic data with one daily measurement per device, so it shows the pipeline works, not that energy forecasts improve. See the pilot evidence and what each part rests on.
In place, on synthetic data only: the energy record; a statistics workload that releases one noised daily mean of a field the policy names, with a receipt; and this task’s method end to end: a next-day forecast of one field trained with DP-SGD on 8 sealed days, scored inside the workload on a whole operator’s fleet it never saw, as when a new operator joins, and against one operator’s data alone, with only noised errors released. The live demo runs it on 1000 synthetic storage units of four synthetic operators that run their storage differently (price arbitrage, commercial peak shaving, solar time-shift, a mixed portfolio), by profiles we wrote, not measured. A new operator can also adapt the released model to a week of its own labels on its own machine, and keeps it only if it beats the released model on its later days (ADR 0020). Not yet in place: a founding partner, any real data, and any measured gain on a real fleet. Training across several enclaves or on GPUs is not needed for this task and remains on the roadmap.
How to join
Tell us what your fleet is and what you would want forecast. An overview is enough; please do not send data or anything confidential.
- The kind of equipment and roughly how many sites, and in which regions
- How much daily history you keep, and how your devices or gateways connect
- The forecasting question you care about, and how you would judge a better answer
Founding data partners, model teams and compute partners are welcome.
Or email info@tlay.io. Nothing is sent from this site.